Á¦Ç°Á¤º¸ |
|
SCION Instruments |
- SCION 456 GC |
- SCION SQ & TQ |
EST analytical |
- Evolution Purge and Trap Concentrator |
- Centurion Purge and Trap Autosampler |
- FLEX Headspace/SPME Autosampler |
ionSense |
- Direct Analysis in Real Time |
EPREP |
- ePrep Sample Preparation Workstation |
- uSPEed Cartridges |
- uXact3 Programmable Digital Syringe Driver |
Edinburgh Instruments |
- FS5 |
- RM5 |
- FLS1000 |
- LP980 |
- LifeSpec II Spectrometer |
- Mini-tau |
- DS5 |
Software |
|
|
|
|
HOME > Á¦Ç°Á¤º¸ > Edinburgh Instruments > FS5 |
|
FS5ºÐ¼®±â¼ú¿¡¼ ÃÖ°íÀÇ ±â¼ú°ú ¼Ö·ç¼ÇÀ» Á¦°øÇÕ´Ï´Ù. |
|
|
|
FS5 Fluorescence Spectrometers |
|
 |
Á¦Ç°ÀÇ Æ¯ÀåÁ¡ |
Specification |
°ßÀû¼ ¿äûī´Ù·Î±× ¿äû |
|
- ÇϳªÀÇ Àåºñ¿¡ ¿©·¯ °³ÀÇ °ËÃâ±â Æ÷Æ®°¡ ÀÖ¾î ÃÖ´ë 1,650nm±îÁö ÃøÁ¤
- >6,000:1 Water Raman SNR, °í°¨µµ·Î ¸Å¿ì ¾àÇÑ Çü±¤ ½ÅÈ£±îÁö °ËÃâ °¡´É
- 3°³ÀÇ Ç¥ÁØ °ËÃâ±â, ±¤¿ø º¯µ¿À» º¸Á¤Çϱâ À§ÇÑ ±âÁØ °ËÃâ±â, Èí±¤µµ¸¦ À§ÇÑ Åõ°ú °ËÃâ±â
- ÃÖ°í °¨µµ¸¦ À§ÇÑ TCSPC (Time Correlated Single photon counting) °ËÃâ±â
- »ç¿ëÀÚÀÇ ½Ã°£°ú ³ë·ÂÀ» Àý¾à½ÃÄÑÁÖ´Â Plug & Play »ùÇà ¸ðµâ, ÀÚµ¿ »ùÇà ¸ðµâ ÀÎ½Ä ¹×
ÃʱâÈ ±â´É
- ´Ù¾çÇÑ ½Ã·á ºÐ¼®À» ÇÒ ¼ö ÀÖ´Â ±¤¹üÀ§ÇÑ Sample Compartment ¸ðµâ |
|
 |
|
Á¦Ç°ÀÇ ÀÀ¿ë |
|
 |
|
Á¦Ç°ÀÇ Æ¯ÀåÁ¡ |
Specification |
°ßÀû¼ ¿äûī´Ù·Î±× ¿äû |
|
STANDARD CONFIGURATION |
Optics |
All-reflective for wavelength independent focus with high brightness (small focus) at the sample |
Detection Technique |
Single Photon Counting |
Light Source |
150 W CW Ozone-free Xenon arc lamp |
Monochromators |
Czerny-Turner with plane gratings for accurate focus at all wavelengths and minimum stray light |
Spectral Coverage - Excitation |
230 nm - 1000 nm |
Spectral Coverage - Emission |
200 nm - >870 nm |
Filter wheels |
Fully automated; included in both the excitation and emission monochromators |
Bandpass - Excitaion/Emission |
0 - 30 nm, continuously adjustable |
Wavelength Accuracy |
¡¾ 0.5 nm |
Scan Speed - Excitation/Emission |
100 nm/s |
Integration Time |
from 1 ms |
DETECTORS |
Emission Detector |
Single Photon Counting, PMT-900, cooled and stabilised, 200 nm - 900 nm |
Reference Detector |
UV enhanced silicon photodiode, 200 nm - 1000 nm |
Absorbance Detector |
UV enhanced silicon photodiode, 200 nm - 1000 nm |
Absorbance Range |
0 - 2 A |
Absorbance Accuracy |
¡¾ 0.01 A |
SENSITIVITY |
Water Raman Signal |
400,000 cps at 397 nm emission, excitation 350 nm, 5 nm bandpass, 1 s integration time |
Signal-to-Noise Ratio |
>6,000:1 (SQRT) |
DIMENSIONS |
W x D x H |
104 cm x 59 cm x 32 cm |
Weight |
55 kg |
|
|
|
|
|
|
|